Ⅰ. Increased PPE Requirements
The Photosynthetic Photon Efficacy (PPE) must exceed 2.5 μmol/J (with a tolerance of -5%).
Ⅱ. Elimination of Horticultural Lighting Source Categories
Due to the relatively lower number of horticultural light sources applying for DLC certification compared to the full fixture category, DLC has removed the standard scope for the horticultural light source category to simplify the requirements.
- Defining the coverage of LED models with different dominant wavelengths acceptable under LM80 limitations.
【LM-80 applicability claims where the difference from the nominal peak or dominant wavelength of the LM-80 tested LED to the nominal peak or dominant wavelength of a different LED is beyond +/-15nm will be rejected.】
- Tunable spectrum products are categorized into custom spectrum tuning and preset spectrum tuning.